Name

gnt-node - Node administration

Synopsis

gnt-node {command} [arguments...]

DESCRIPTION

The gnt-node is used for managing the (physical) nodes in the Ganeti system.

COMMANDS

ADD

add [--readd] [{-s|--secondary-ip} secondary_ip]
[{-g|--node-group} nodegroup]
[--master-capable=yes|no] [--vm-capable=yes|no]
[--node-parameters ndparams]
[--disk-state diskstate]
[--hypervisor-state hvstate]
{nodename}

Adds the given node to the cluster.

This command is used to join a new node to the cluster. You will have to provide the password for root of the node to be able to add the node in the cluster. The command needs to be run on the Ganeti master.

Note that the command is potentially destructive, as it will forcibly join the specified host to the cluster, not paying attention to its current status (it could be already in a cluster, etc.)

The -s (--secondary-ip) is used in dual-home clusters and specifies the new node's IP in the secondary network. See the discussion in gnt-cluster(8) for more information.

In case you're readding a node after hardware failure, you can use the --readd parameter. In this case, you don't need to pass the secondary IP again, it will be reused from the cluster. Also, the drained and offline flags of the node will be cleared before re-adding it.

The -g (--node-group) option is used to add the new node into a specific node group, specified by UUID or name. If only one node group exists you can skip this option, otherwise it's mandatory.

The vm_capable, master_capable, ndparams, diskstate and hvstate options are described in ganeti(7), and are used to set the properties of the new node.

The command performs some operations that change the state of the master and the new node, like copying certificates and starting the node daemon on the new node, or updating /etc/hosts on the master node. If the command fails at a later stage, it doesn't undo such changes. This should not be a problem, as a successful run of gnt-node add will bring everything back in sync.

If the node was previously part of another cluster and still has daemons running, the node-cleanup tool can be run on the machine to be added to clean remains of the previous cluster from the node.

Example:

# gnt-node add node5.example.com
# gnt-node add -s 192.0.2.5 node5.example.com
# gnt-node add -g group2 -s 192.0.2.9 node9.group2.example.com

EVACUATE

evacuate [-f] [--early-release] [--submit] [--print-job-id]
[{-I|--iallocator} NAME | {-n|--new-secondary} destination_node]
[{-p|--primary-only} | {-s|--secondary-only} ]
{node}

This command will move instances away from the given node. If --primary-only is given, only primary instances are evacuated, with --secondary-only only secondaries. If neither is given, all instances are evacuated. It works only for instances having a drbd disk template.

The new location for the instances can be specified in two ways:

The --early-release changes the code so that the old storage on node being evacuated is removed early (before the resync is completed) and the internal Ganeti locks are also released for both the current secondary and the new secondary, thus allowing more parallelism in the cluster operation. This should be used only when recovering from a disk failure on the current secondary (thus the old storage is already broken) or when the storage on the primary node is known to be fine (thus we won't need the old storage for potential recovery).

Note that this command is equivalent to using per-instance commands for each affected instance individually:

Note that the iallocator currently only considers disk information of the default disk template, even if the instance's disk templates differ from that.

See ganeti(7) for a description of --submit and other common options.

Example:

# gnt-node evacuate -I hail node3.example.com

Note that, due to an issue with the iallocator interface, evacuation of all instances at once is not yet implemented. Full evacuation can currently be achieved by sequentially evacuating primaries and secondaries.

# gnt-node evacuate -p node3.example.com
# gnt-node evacuate -s node3.example.com

FAILOVER

failover [-f] [--ignore-consistency] {node}

This command will fail over all instances having the given node as primary to their secondary nodes. This works only for instances having a drbd disk template.

Note that failover will stop any running instances on the given node and restart them again on the new primary. See also FAILOVER in gnt-instance(8).

Normally the failover will check the consistency of the disks before failing over the instance. If you are trying to migrate instances off a dead node, this will fail. Use the --ignore-consistency option for this purpose.

Example:

# gnt-node failover node1.example.com

INFO

info [node...]

Show detailed information about the nodes in the cluster. If you don't give any arguments, all nodes will be shows, otherwise the output will be restricted to the given names.

LIST

list
[--no-headers] [--separator=SEPARATOR]
[--units=UNITS] [-v] [{-o|--output} [+]FIELD,...]
[--filter]
[node...]

Lists the nodes in the cluster.

The --no-headers option will skip the initial header line. The --separator option takes an argument which denotes what will be used between the output fields. Both these options are to help scripting.

The units used to display the numeric values in the output varies, depending on the options given. By default, the values will be formatted in the most appropriate unit. If the --separator option is given, then the values are shown in mebibytes to allow parsing by scripts. In both cases, the --units option can be used to enforce a given output unit.

Queries of nodes will be done in parallel with any running jobs. This might give inconsistent results for the free disk/memory.

The -v option activates verbose mode, which changes the display of special field states (see ganeti(7)).

The -o (--output) option takes a comma-separated list of output fields. The available fields and their meaning are:

bootid

Random UUID renewed for each system reboot, can be used for detecting reboots by tracking changes

cnodes

Number of NUMA domains on node (if exported by hypervisor)

cnos

Number of logical processors used by the node OS (dom0 for Xen)

csockets

Number of physical CPU sockets (if exported by hypervisor)

ctime

Creation timestamp

ctotal

Number of logical processors

custom_ndparams

Custom node parameters

dfree

Available storage space in storage unit

disk_state

Disk state

drained

Whether node is drained

dtotal

Total storage space in storage unit used for instance disk allocation

group

Node group

group.uuid

UUID of node group

hv_state

Hypervisor state

master

Whether node is master

master_candidate

Whether node is a master candidate

master_capable

Whether node can become a master candidate

mfree

Memory available for instance allocations

mnode

Amount of memory used by node (dom0 for Xen)

mtime

Modification timestamp

mtotal

Total amount of memory of physical machine

name

Node name

ndp/exclusive_storage

The "exclusive_storage" node parameter

ndp/oob_program

The "oob_program" node parameter

ndp/ovs

The "ovs" node parameter

ndp/ovs_link

The "ovs_link" node parameter

ndp/ovs_name

The "ovs_name" node parameter

ndp/spindle_count

The "spindle_count" node parameter

ndparams

Merged node parameters

offline

Whether node is marked offline

pinst_cnt

Number of instances with this node as primary

pinst_list

List of instances with this node as primary

pip

Primary IP address

powered

Whether node is thought to be powered on

role

Node role; "M" for master, "C" for master candidate, "R" for regular, "D" for drained, "O" for offline

serial_no

Node object serial number, incremented on each modification

sinst_cnt

Number of instances with this node as secondary

sinst_list

List of instances with this node as secondary

sip

Secondary IP address

spfree

Available spindles in volume group (exclusive storage only)

sptotal

Total spindles in volume group (exclusive storage only)

tags

Tags

uuid

Node UUID

vm_capable

Whether node can host instances

If the value of the option starts with the character +, the new fields will be added to the default list. This allows one to quickly see the default list plus a few other fields, instead of retyping the entire list of fields.

Note that some of these fields are known from the configuration of the cluster (e.g. name, pinst, sinst, pip, sip) and thus the master does not need to contact the node for this data (making the listing fast if only fields from this set are selected), whereas the other fields are "live" fields and require a query to the cluster nodes.

Depending on the virtualization type and implementation details, the mtotal, mnode and mfree fields may have slightly varying meanings. For example, some solutions share the node memory with the pool of memory used for instances (KVM), whereas others have separate memory for the node and for the instances (Xen).

Note that the field 'dtotal' and 'dfree' refer to the storage type that is defined by the default disk template. The default disk template is the first on in the list of cluster-wide enabled disk templates and can be set with gnt-cluster modify. Currently, only the disk templates 'plain', 'drbd', 'file', and 'sharedfile' support storage reporting, for all others '0' is displayed.

If exactly one argument is given and it appears to be a query filter (see ganeti(7)), the query result is filtered accordingly. For ambiguous cases (e.g. a single field name as a filter) the --filter (-F) option forces the argument to be treated as a filter (e.g. gnt-node list -F master_candidate).

If no node names are given, then all nodes are queried. Otherwise, only the given nodes will be listed.

LIST-DRBD

list-drbd [--no-headers] [--separator=SEPARATOR] node

Lists the mapping of DRBD minors for a given node. This outputs a static list of fields (it doesn't accept the --output option), as follows:

Node

The (full) name of the node we are querying

Minor

The DRBD minor

Instance

The instance the DRBD minor belongs to

Disk

The disk index that the DRBD minor belongs to

Role

Either primary or secondary, denoting the role of the node for the instance (note: this is not the live status of the DRBD device, but the configuration value)

PeerNode

The node that the minor is connected to on the other end

This command can be used as a reverse lookup (from node and minor) to a given instance, which can be useful when debugging DRBD issues.

Note that this command queries Ganeti via ganeti-confd(8), so it won't be available if support for confd has not been enabled at build time; furthermore, in Ganeti 2.6 this is only available via the Haskell version of confd (again selected at build time).

LIST-FIELDS

list-fields [field...]

Lists available fields for nodes.

MIGRATE

migrate [-f] [--non-live] [--migration-mode=live|non-live]
[--ignore-ipolicy] [--submit] [--print-job-id] {node}

This command will migrate all instances having the given node as primary to their secondary nodes. This works only for instances having a drbd disk template.

As for the gnt-instance migrate command, the options --no-live, --migration-mode and --no-runtime-changes can be given to influence the migration type.

If --ignore-ipolicy is given any instance policy violations occurring during this operation are ignored.

See ganeti(7) for a description of --submit and other common options.

Example:

# gnt-node migrate node1.example.com

MODIFY

modify [-f] [--submit] [--print-job-id]
[{-C|--master-candidate} yes|no]
[{-D|--drained} yes|no] [{-O|--offline} yes|no]
[--master-capable=yes|no] [--vm-capable=yes|no] [--auto-promote]
[{-s|--secondary-ip} secondary_ip]
[--node-parameters ndparams]
[--node-powered=yes|no]
[--hypervisor-state hvstate]
[--disk-state diskstate]
{node}

This command changes the role of the node. Each options takes either a literal yes or no, and only one option should be given as yes. The meaning of the roles and flags are described in the manpage ganeti(7).

The option --node-powered can be used to modify state-of-record if it doesn't reflect the reality anymore.

In case a node is demoted from the master candidate role, the operation will be refused unless you pass the --auto-promote option. This option will cause the operation to lock all cluster nodes (thus it will not be able to run in parallel with most other jobs), but it allows automated maintenance of the cluster candidate pool. If locking all cluster node is too expensive, another option is to promote manually another node to master candidate before demoting the current one.

Example (setting a node offline, which will demote it from master candidate role if is in that role):

# gnt-node modify --offline=yes node1.example.com

The -s (--secondary-ip) option can be used to change the node's secondary ip. No drbd instances can be running on the node, while this operation is taking place. Remember that the secondary ip must be reachable from the master secondary ip, when being changed, so be sure that the node has the new IP already configured and active. In order to convert a cluster from single homed to multi-homed or vice versa --force is needed as well, and the target node for the first change must be the master.

See ganeti(7) for a description of --submit and other common options.

Example (setting the node back to online and master candidate):

# gnt-node modify --offline=no --master-candidate=yes node1.example.com

REMOVE

remove {nodename}

Removes a node from the cluster. Instances must be removed or migrated to another cluster before.

Example:

# gnt-node remove node5.example.com

VOLUMES

volumes [--no-headers] [--human-readable]
[--separator=SEPARATOR] [{-o|--output} FIELDS]
[node...]

Lists all logical volumes and their physical disks from the node(s) provided.

The --no-headers option will skip the initial header line. The --separator option takes an argument which denotes what will be used between the output fields. Both these options are to help scripting.

The units used to display the numeric values in the output varies, depending on the options given. By default, the values will be formatted in the most appropriate unit. If the --separator option is given, then the values are shown in mebibytes to allow parsing by scripts. In both cases, the --units option can be used to enforce a given output unit.

The -o (--output) option takes a comma-separated list of output fields. The available fields and their meaning are:

node

the node name on which the volume exists

phys

the physical drive (on which the LVM physical volume lives)

vg

the volume group name

name

the logical volume name

size

the logical volume size

instance

The name of the instance to which this volume belongs, or (in case it's an orphan volume) the character "-"

Example:

# gnt-node volumes node5.example.com
Node              PhysDev   VG    Name                                 Size Instance
node1.example.com /dev/hdc1 xenvg instance1.example.com-sda_11000.meta 128  instance1.example.com
node1.example.com /dev/hdc1 xenvg instance1.example.com-sda_11001.data 256  instance1.example.com

LIST-STORAGE

list-storage [--no-headers] [--human-readable]
[--separator=SEPARATOR] [--storage-type=STORAGE_TYPE]
[{-o|--output} FIELDS]
[node...]

Lists the available storage units and their details for the given node(s).

The --no-headers option will skip the initial header line. The --separator option takes an argument which denotes what will be used between the output fields. Both these options are to help scripting.

The units used to display the numeric values in the output varies, depending on the options given. By default, the values will be formatted in the most appropriate unit. If the --separator option is given, then the values are shown in mebibytes to allow parsing by scripts. In both cases, the --units option can be used to enforce a given output unit.

The --storage-type option can be used to choose a storage unit type. Possible choices are lvm-pv, lvm-vg or file.

The -o (--output) option takes a comma-separated list of output fields. The available fields and their meaning are:

node

the node name on which the volume exists

type

the type of the storage unit (currently just what is passed in via --storage-type)

name

the path/identifier of the storage unit

size

total size of the unit; for the file type see a note below

used

used space in the unit; for the file type see a note below

free

available disk space

allocatable

whether we the unit is available for allocation (only lvm-pv can change this setting, the other types always report true)

Note that for the "file" type, the total disk space might not equal to the sum of used and free, due to the method Ganeti uses to compute each of them. The total and free values are computed as the total and free space values for the filesystem to which the directory belongs, but the used space is computed from the used space under that directory only, which might not be necessarily the root of the filesystem, and as such there could be files outside the file storage directory using disk space and causing a mismatch in the values.

Example:

node1# gnt-node list-storage node2
Node  Type   Name        Size Used   Free Allocatable
node2 lvm-pv /dev/sda7 673.8G 1.5G 672.3G Y
node2 lvm-pv /dev/sdb1 698.6G   0M 698.6G Y

MODIFY-STORAGE

modify-storage [--allocatable={yes|no}] [--submit] [--print-job-id]
{node} {storage-type} {volume-name}

Modifies storage volumes on a node. Only LVM physical volumes can be modified at the moment. They have a storage type of "lvm-pv".

Example:

# gnt-node modify-storage --allocatable no node5.example.com lvm-pv /dev/sdb1

REPAIR-STORAGE

repair-storage [--ignore-consistency] ]--submit]
{node} {storage-type} {volume-name}

Repairs a storage volume on a node. Only LVM volume groups can be repaired at this time. They have the storage type "lvm-vg".

On LVM volume groups, repair-storage runs vgreduce --removemissing.

Caution: Running this command can lead to data loss. Use it with care.

The --ignore-consistency option will ignore any inconsistent disks (on the nodes paired with this one). Use of this option is most likely to lead to data-loss.

Example:

# gnt-node repair-storage node5.example.com lvm-vg xenvg

POWERCYCLE

powercycle [--yes] [--force] [--submit] [--print-job-id] {node}

This command (tries to) forcefully reboot a node. It is a command that can be used if the node environment is broken, such that the admin can no longer login over SSH, but the Ganeti node daemon is still working.

Note that this command is not guaranteed to work; it depends on the hypervisor how effective is the reboot attempt. For Linux, this command requires the kernel option CONFIG_MAGIC_SYSRQ to be enabled.

The --yes option can be used to skip confirmation, while the --force option is needed if the target node is the master node.

See ganeti(7) for a description of --submit and other common options.

POWER

power [--force] [--ignore-status] [--all] [--power-delay] on|off|cycle|status [nodes]

This command calls out to out-of-band management to change the power state of given node. With status you get the power status as reported by the out-of-band management script.

Note that this command will only work if the out-of-band functionality is configured and enabled on the cluster. If this is not the case, please use the powercycle command above.

Using --force you skip the confirmation to do the operation. Currently this only has effect on off and cycle. On those two you can not operate on the master. However, the command will provide you with the command to invoke to operate on the master nerver-mind. This is considered harmful and Ganeti does not support the use of it.

Providing --ignore-status will ignore the offline=N state of a node and continue with power off.

--power-delay specifies the time in seconds (factions allowed) waited between powering on the next node. This is by default 2 seconds but can increased if needed with this option.

nodes are optional. If not provided it will call out for every node in the cluster. Except for the off and cycle command where you've to explicit use --all to select all.

HEALTH

health [nodes]

This command calls out to out-of-band management to ask for the health status of all or given nodes. The health contains the node name and then the items element with their status in a item=status manner. Where item is script specific and status can be one of OK, WARNING, CRITICAL or UNKNOWN. Items with status WARNING or CRITICAL are logged and annotated in the command line output.

RESTRICTED-COMMAND

restricted-command [-M] [--sync]
{ -g group command | command nodes... }

Executes a restricted command on the specified nodes. Restricted commands are not arbitrary, but must reside in /etc/ganeti/restricted-commands on a node, either as a regular file or as a symlink. The directory must be owned by root and not be world- or group-writable. If a command fails verification or otherwise fails to start, the node daemon log must be consulted for more detailed information.

Example for running a command on two nodes:

# gnt-node restricted-command mycommand \
  node1.example.com node2.example.com

The -g option can be used to run a command only on a specific node group, e.g.:

# gnt-node restricted-command -g default mycommand

The -M option can be used to prepend the node name to all command output lines. --sync forces the opcode to acquire the node lock(s) in exclusive mode.

Tags

ADD-TAGS

add-tags [--from file] {nodename} {tag...}

Add tags to the given node. If any of the tags contains invalid characters, the entire operation will abort.

If the --from option is given, the list of tags will be extended with the contents of that file (each line becomes a tag). In this case, there is not need to pass tags on the command line (if you do, both sources will be used). A file name of - will be interpreted as stdin.

LIST-TAGS

list-tags {nodename}

List the tags of the given node.

REMOVE-TAGS

remove-tags [--from file] {nodename} {tag...}

Remove tags from the given node. If any of the tags are not existing on the node, the entire operation will abort.

If the --from option is given, the list of tags to be removed will be extended with the contents of that file (each line becomes a tag). In this case, there is not need to pass tags on the command line (if you do, tags from both sources will be removed). A file name of - will be interpreted as stdin.

REPORTING BUGS

Report bugs to project website or contact the developers using the Ganeti mailing list.

SEE ALSO

Ganeti overview and specifications: ganeti(7) (general overview), ganeti-os-interface(7) (guest OS definitions), ganeti-extstorage-interface(7) (external storage providers).

Ganeti commands: gnt-cluster(8) (cluster-wide commands), gnt-job(8) (job-related commands), gnt-node(8) (node-related commands), gnt-instance(8) (instance commands), gnt-os(8) (guest OS commands), gnt-storage(8) (storage commands), gnt-group(8) (node group commands), gnt-backup(8) (instance import/export commands), gnt-debug(8) (debug commands).

Ganeti daemons: ganeti-watcher(8) (automatic instance restarter), ganeti-cleaner(8) (job queue cleaner), ganeti-noded(8) (node daemon), ganeti-masterd(8) (master daemon), ganeti-rapi(8) (remote API daemon).

Ganeti htools: htools(1) (generic binary), hbal(1) (cluster balancer), hspace(1) (capacity calculation), hail(1) (IAllocator plugin), hscan(1) (data gatherer from remote clusters), hinfo(1) (cluster information printer), mon-collector(7) (data collectors interface).

COPYRIGHT

Copyright (C) 2006-2014 Google Inc. All rights reserved.

Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met:

1. Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimer.

2. Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer in the documentation and/or other materials provided with the distribution.

THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.