Hotplug

This is a design document detailing the implementation of device hotplugging in Ganeti. The logic used is hypervisor agnostic but still the initial implementation will target the KVM hypervisor. The implementation adds python-fdsend as a new dependency. In case it is not installed hotplug will not be possible and the user will be notified with a warning.

Current state and shortcomings

Currently, Ganeti supports addition/removal/modification of devices (NICs, Disks) but the actual modification takes place only after rebooting the instance. To this end an instance cannot change network, get a new disk etc. without a hard reboot.

Until now, in case of KVM hypervisor, code does not name devices nor places them in specific PCI slots. Devices are appended in the KVM command and Ganeti lets KVM decide where to place them. This means that there is a possibility a device that resides in PCI slot 5, after a reboot (due to another device removal) to be moved to another PCI slot and probably get renamed too (due to udev rules, etc.).

In order for a migration to succeed, the process on the target node should be started with exactly the same machine version, CPU architecture and PCI configuration with the running process. During instance creation/startup ganeti creates a KVM runtime file with all the necessary information to generate the KVM command. This runtime file is used during instance migration to start a new identical KVM process. The current format includes the fixed part of the final KVM command, a list of NICs’, and hvparams dict. It does not favor easy manipulations concerning disks, because they are encapsulated in the fixed KVM command.

Proposed changes

For the case of the KVM hypervisor, QEMU exposes 32 PCI slots to the instance. Disks and NICs occupy some of these slots. Recent versions of QEMU have introduced monitor commands that allow addition/removal of PCI devices. Devices are referenced based on their name or position on the virtual PCI bus. To be able to use these commands, we need to be able to assign each device a unique name.

To keep track where each device is plugged into, we add the pci slot to Disk and NIC objects, but we save it only in runtime files, since it is hypervisor specific info. This is added for easy object manipulation and is ensured not to be written back to the config.

We propose to make use of QEMU 1.7 QMP commands so that modifications to devices take effect instantly without the need for hard reboot. The only change exposed to the end-user will be the addition of a --hotplug option to the gnt-instance modify command.

Upon hotplugging the PCI configuration of an instance is changed. Runtime files should be updated correspondingly. Currently this is impossible in case of disk hotplug because disks are included in command line entry of the runtime file, contrary to NICs that are correctly treated separately. We change the format of runtime files, we remove disks from the fixed KVM command and create new entry containing them only. KVM options concerning disk are generated during _ExecuteKVMCommand(), just like NICs.

Design decisions

Which should be each device ID? Currently KVM does not support arbitrary IDs for devices; supported are only names starting with a letter, max 32 chars length, and only including ‘.’ ‘_’ ‘-‘ special chars. For debugging purposes and in order to be more informative, device will be named after: <device type>-<part of uuid>-pci-<slot>.

Who decides where to hotplug each device? As long as this is a hypervisor specific matter, there is no point for the master node to decide such a thing. Master node just has to request noded to hotplug a device. To this end, hypervisor specific code should parse the current PCI configuration (i.e. query-pci QMP command), find the first available slot and hotplug the device. Having noded to decide where to hotplug a device we ensure that no error will occur due to duplicate slot assignment (if masterd keeps track of PCI reservations and noded fails to return the PCI slot that the device was plugged into then next hotplug will fail).

Where should we keep track of devices’ PCI slots? As already mentioned, we must keep track of devices PCI slots to successfully migrate instances. First option is to save this info to config data, which would allow us to place each device at the same PCI slot after reboot. This would require to make the hypervisor return the PCI slot chosen for each device, and storing this information to config data. Additionally the whole instance configuration should be returned with PCI slots filled after instance start and each instance should keep track of current PCI reservations. We decide not to go towards this direction in order to keep it simple and do not add hypervisor specific info to configuration data (pci_reservations at instance level and pci at device level). For the aforementioned reason, we decide to store this info only in KVM runtime files.

Where to place the devices upon instance startup? QEMU has by default 4 pre-occupied PCI slots. So, hypervisor can use the remaining ones for disks and NICs. Currently, PCI configuration is not preserved after reboot. Each time an instance starts, KVM assigns PCI slots to devices based on their ordering in Ganeti configuration, i.e. the second disk will be placed after the first, the third NIC after the second, etc. Since we decided that there is no need to keep track of devices PCI slots, there is no need to change current functionality.

How to deal with existing instances? Hotplug depends on runtime file manipulation. It stores there pci info and every device the kvm process is currently using. Existing files have no pci info in devices and have block devices encapsulated inside kvm_cmd entry. Thus hotplugging of existing devices will not be possible. Still migration and hotplugging of new devices will succeed. The workaround will happen upon loading kvm runtime: if we detect old style format we will add an empty list for block devices and upon saving kvm runtime we will include this empty list as well. Switching entirely to new format will happen upon instance reboot.

Configuration changes

The NIC and Disk objects get one extra slot: pci. It refers to PCI slot that the device gets plugged into.

In order to be able to live migrate successfully, runtime files should be updated every time a live modification (hotplug) takes place. To this end we change the format of runtime files. The KVM options referring to instance’s disks are no longer recorded as part of the KVM command line. Disks are treated separately, just as we treat NICs right now. We insert and remove entries to reflect the current PCI configuration.

Backend changes

Introduce one new RPC call:

  • hotplug_device(DEVICE_TYPE, ACTION, device, ...)

where DEVICE_TYPE can be either NIC or Disk, and ACTION either REMOVE or ADD.

Hypervisor changes

We implement hotplug on top of the KVM hypervisor. We take advantage of QEMU 1.7 QMP commands (device_add, device_del, blockdev-add, netdev_add, netdev_del). Since drive_del is not yet implemented in QMP we use the one of HMP. QEMU refers to devices based on their id. We use uuid to name them properly. If a device is about to be hotplugged we parse the output of query-pci and find the occupied PCI slots. We choose the first available and the whole device object is appended to the corresponding entry in the runtime file.

Concerning NIC handling, we build on the top of the existing logic (first create a tap with _OpenTap() and then pass its file descriptor to the KVM process). To this end we need to pass access rights to the corresponding file descriptor over the QMP socket (UNIX domain socket). The open file is passed as a socket-level control message (SCM), using the fdsend python library.

User interface

The new --hotplug option to gnt-instance modify is introduced, which forces live modifications.

Enabling hotplug

Hotplug will be optional during gnt-instance modify. For existing instance, after installing a version that supports hotplugging we have the restriction that hotplug will not be supported for existing devices. The reason is that old runtime files lack of:

  1. Device pci configuration info.
  2. Separate block device entry.

Hotplug will be supported only for KVM in the first implementation. For all other hypervisors, backend will raise an Exception case hotplug is requested.

NIC Hotplug

The user can add/modify/remove NICs either with hotplugging or not. If a NIC is to be added a tap is created first and configured properly with kvm-vif-bridge script. Then the instance gets a new network interface. Since there is no QEMU monitor command to modify a NIC, we modify a NIC by temporary removing the existing one and adding a new with the new configuration. When removing a NIC the corresponding tap gets removed as well.

gnt-instance modify --net add --hotplug test
gnt-instance modify --net 1:mac=aa:00:00:55:44:33 --hotplug test
gnt-instance modify --net 1:remove --hotplug test

Disk Hotplug

The user can add and remove disks with hotplugging or not. QEMU monitor supports resizing of disks, however the initial implementation will support only disk addition/deletion.

gnt-instance modify --disk add:size=1G --hotplug test
gnt-instance modify --net 1:remove --hotplug test

Dealing with chroot and uid pool (and disks in general)

The design so far covers all issues that arise without addressing the case where the kvm process will not run with root privileges. Specifically:

  • in case of chroot, the kvm process cannot see the newly created device
  • in case of uid pool security model, the kvm process is not allowed to access the device

For NIC hotplug we address this problem by using the getfd QMP command and passing the file descriptor to the kvm process over the monitor socket using SCM_RIGHTS. For disk hotplug and in case of uid pool we can let the hypervisor code temporarily chown() the device before the actual hotplug. Still this is insufficient in case of chroot. In this case, we need to mknod() the device inside the chroot. Both workarounds can be avoided, if we make use of the add-fd QMP command, that was introduced in version 1.7. This command is the equivalent of NICs’ get-fd` for disks and will allow disk hotplug in every case. So, if the QMP does not support the add-fd command, we will not allow disk hotplug and notify the user with the corresponding warning.