======================= Ganeti monitoring agent ======================= .. contents:: :depth: 4 This is a design document detailing the implementation of a Ganeti monitoring agent report system, that can be queried by a monitoring system to calculate health information for a Ganeti cluster. Current state and shortcomings ============================== There is currently no monitoring support in Ganeti. While we don't want to build something like Nagios or Pacemaker as part of Ganeti, it would be useful if such tools could easily extract information from a Ganeti machine in order to take actions (example actions include logging an outage for future reporting or alerting a person or system about it). Proposed changes ================ Each Ganeti node should export a status page that can be queried by a monitoring system. Such status page will be exported on a network port and will be encoded in JSON (simple text) over HTTP. The choice of json is obvious as we already depend on it in Ganeti and thus we don't need to add extra libraries to use it, as opposed to what would happen for XML or some other markup format. Location of agent report ------------------------ The report will be available from all nodes, and be concerned for all node-local resources. This allows more real-time information to be available, at the cost of querying all nodes. Information reported -------------------- The monitoring agent system will report on the following basic information: - Instance status - Instance disk status - Status of storage for instances - Ganeti daemons status, CPU usage, memory footprint - Hypervisor resources report (memory, CPU, network interfaces) - Node OS resources report (memory, CPU, network interfaces) - Information from a plugin system Instance status +++++++++++++++ At the moment each node knows which instances are running on it, which instances it is primary for, but not the cause why an instance might not be running. On the other hand we don't want to distribute full instance "admin" status information to all nodes, because of the performance impact this would have. As such we propose that: - Any operation that can affect instance status will have an optional "reason" attached to it (at opcode level). This can be used for example to distinguish an admin request, from a scheduled maintenance or an automated tool's work. If this reason is not passed, Ganeti will just use the information it has about the source of the request: for example a cli shutdown operation will have "cli:shutdown" as a reason, a cli failover operation will have "cli:failover". Operations coming from the remote API will use "rapi" instead of "cli". Of course setting a real site-specific reason is still preferred. - RPCs that affect the instance status will be changed so that the "reason" and the version of the config object they ran on is passed to them. They will then export the new expected instance status, together with the associated reason and object version to the status report system, which then will export those themselves. Monitoring and auditing systems can then use the reason to understand the cause of an instance status, and they can use the object version to understand the freshness of their data even in the absence of an atomic cross-node reporting: for example if they see an instance "up" on a node after seeing it running on a previous one, they can compare these values to understand which data is freshest, and repoll the "older" node. Of course if they keep seeing this status this represents an error (either an instance continuously "flapping" between nodes, or an instance is constantly up on more than one), which should be reported and acted upon. The instance status will be on each node, for the instances it is primary for and will contain at least: - The instance name - The instance UUID (stable on name change) - The instance running status (up or down) - The uptime, as detected by the hypervisor - The timestamp of last known change - The timestamp of when the status was last checked (see caching, below) - The last known reason for change, if any More information about all the fields and their type will be available in the "Format of the report" section. Note that as soon as a node knows it's not the primary anymore for an instance it will stop reporting status for it: this means the instance will either disappear, if it has been deleted, or appear on another node, if it's been moved. Instance Disk status ++++++++++++++++++++ As for the instance status Ganeti has now only partial information about its instance disks: in particular each node is unaware of the disk to instance mapping, that exists only on the master. For this design doc we plan to fix this by changing all RPCs that create a backend storage or that put an already existing one in use and passing the relevant instance to the node. The node can then export these to the status reporting tool. While we haven't implemented these RPC changes yet, we'll use confd to fetch this information in the data collector. Since Ganeti supports many type of disks for instances (drbd, rbd, plain, file) we will export both a "generic" status which will work for any type of disk and will be very opaque (at minimum just an "healthy" or "error" state, plus perhaps some human readable comment and a "per-type" status which will explain more about the internal details but will not be compatible between different storage types (and will for example export the drbd connection status, sync, and so on). Status of storage for instances +++++++++++++++++++++++++++++++ The node will also be reporting on all storage types it knows about for the current node (this is right now hardcoded to the enabled storage types, and in the future tied to the enabled storage pools for the nodegroup). For this kind of information also we will report both a generic health status (healthy or error) for each type of storage, and some more generic statistics (free space, used space, total visible space). In addition type specific information can be exported: for example, in case of error, the nature of the error can be disclosed as a type specific information. Examples of these are "backend pv unavailable" for lvm storage, "unreachable" for network based storage or "filesystem error" for filesystem based implementations. Ganeti daemons status +++++++++++++++++++++ Ganeti will report what information it has about its own daemons: this includes memory usage, uptime, CPU usage. This should allow identifying possible problems with the Ganeti system itself: for example memory leaks, crashes and high resource utilization should be evident by analyzing this information. Ganeti daemons will also be able to export extra internal information to the status reporting, through the plugin system (see below). Hypervisor resources report +++++++++++++++++++++++++++ Each hypervisor has a view of system resources that sometimes is different than the one the OS sees (for example in Xen the Node OS, running as Dom0, has access to only part of those resources). In this section we'll report all information we can in a "non hypervisor specific" way. Each hypervisor can then add extra specific information that is not generic enough be abstracted. Node OS resources report ++++++++++++++++++++++++ Since Ganeti assumes it's running on Linux, it's useful to export some basic information as seen by the host system. This includes number and status of CPUs, memory, filesystems and network intefaces as well as the version of components Ganeti interacts with (Linux, drbd, hypervisor, etc). Note that we won't go into any hardware specific details (e.g. querying a node RAID is outside the scope of this, and can be implemented as a plugin) but we can easily just report the information above, since it's standard enough across all systems. Plugin system +++++++++++++ The monitoring system will be equipped with a plugin system that can export specific local information through it. The plugin system will be in the form of either scripts whose output will be inserted in the report, plain text files which will be inserted into the report, or local unix or network sockets from which the information has to be read. This should allow most flexibility for implementing an efficient system, while being able to keep it as simple as possible. The plugin system is expected to be used by local installations to export any installation specific information that they want to be monitored, about either hardware or software on their systems. Format of the query ------------------- The query will be an HTTP GET request on a particular port. At the beginning it will only be possible to query the full status report. Format of the report -------------------- The report of the will be in JSON format, and it will present an array of report objects. Each report object will be produced by a specific data collector. Each report object includes some mandatory fields, to be provided by all the data collectors, and a field to contain data collector-specific data. Here follows a minimal example of a report:: [ { "name" : "TheCollectorIdentifier", "version" : "1.2", "format_version" : 1, "timestamp" : 1351607182000000000, "data" : { "plugin_specific_data" : "go_here" } }, { "name" : "AnotherDataCollector", "version" : "B", "format_version" : 7, "timestamp" : 1351609526123854000, "data" : { "plugin_specific" : "data", "some_late_data" : { "timestamp" : "SPECIFIC_TIME", ... } } } ] Here is the description of the mandatory fields of each object: name the name of the data collector that produced this part of the report. It is supposed to be unique inside a report. version the version of the data collector that produces this part of the report. Built-in data collectors (as opposed to those implemented as plugins) should have "B" as the version number. format_version the format of what is represented in the "data" field for each data collector might change over time. Every time this happens, the format_version should be changed, so that who reads the report knows what format to expect, and how to correctly interpret it. timestamp the time when the reported data were gathered. Is has to be expressed in nanoseconds since the unix epoch (0:00:00 January 01, 1970). If not enough precision is available (or needed) it can be padded with zeroes. If a report object needs multiple timestamps, it can add more and/or override this one inside its own "data" section. data this field contains all the data generated by the data collector, in its own independently defined format. The monitoring agent could check this syntactically (according to the JSON specifications) but not semantically. Data collectors --------------- In order to ease testing as well as to make it simple to reuse this subsystem it will be possible to run just the "data collectors" on each node without passing through the agent daemon. Each data collector will report specific data about its subsystem and will be documented separately. If a data collector is run independently, it should print on stdout its report, according to the format corresponding to a single data collector report object, as described in the previous paragraph. Mode of operation ----------------- In order to be able to report information fast the monitoring agent daemon will keep an in-memory or on-disk cache of the status, which will be returned when queries are made. The status system will then periodically check resources to make sure the status is up to date. Different parts of the report will be queried at different speeds. These will depend on: - how often they vary (or we expect them to vary) - how fast they are to query - how important their freshness is Of course the last parameter is installation specific, and while we'll try to have defaults, it will be configurable. The first two instead we can use adaptively to query a certain resource faster or slower depending on those two parameters. Implementation place -------------------- The status daemon will be implemented as a standalone Haskell daemon. In the future it should be easy to merge multiple daemons into one with multiple entry points, should we find out it saves resources and doesn't impact functionality. The libekg library should be looked at for easily providing metrics in json format. Implementation order -------------------- We will implement the agent system in this order: - initial example data collectors (eg. for drbd and instance status. Data collector-specific report format TBD). - initial daemon for exporting data - RPC updates for instance status reasons and disk to instance mapping - more data collectors - cache layer for the daemon (if needed) Future work =========== As a future step it can be useful to "centralize" all this reporting data on a single place. This for example can be just the master node, or all the master candidates. We will evaluate doing this after the first node-local version has been developed and tested. Another possible change is replacing the "read-only" RPCs with queries to the agent system, thus having only one way of collecting information from the nodes from a monitoring system and for Ganeti itself. One extra feature we may need is a way to query for only sub-parts of the report (eg. instances status only). This can be done by passing arguments to the HTTP GET, which will be defined when we get to this funtionality. Finally the :doc:`autorepair system design `. system (see its design) can be expanded to use the monitoring agent system as a source of information to decide which repairs it can perform. .. vim: set textwidth=72 : .. Local Variables: .. mode: rst .. fill-column: 72 .. End: